Page 11





04:21:53	Reactor Coolant Makeup Pump B (MU-P-1B) was started.
(0818:30)


04:26:59	Reactor Coolant Makeup Pump C (MU-P-1C) was started, tripped, 
(0827:36)
Approximate	and was restarted.


04:30:00	The Electromatic Re1ief Block Valve (RC-V2) was shut.
(0830:37)
Approximate


04:30:45	Condenser Vacuum Pumps 1A and 1C (VA-P-1A and VA-P-1C) were 
(0831:22)
 		stopped and vacuum was broken. 


04:30:45	Power Operated Emergency Main Steam Dump Valve (MS-V3A) was opened.
(0831:22)
Approximate


04:54:00	The Electromatic Relief Block Valve (RC-V2) was opened.
(0854:37)   
Approximate


05:18:00	The E1ectromatic Relief Block Valve (RC-V2) was shut.
(0918:37)


05:54:00	Operator commenced filling Steam Generator A to 99% on the Operating
(0954:37)
Approximate	Range instrumentation. 
   

07:30:00	Electromatic Relief Block Valve (RC-V2) and the Pressurizer Spray
(1130:37)
Approximate	Valve (RC-V1) were opened.
   

08:l1:26	Core Flood Tank A high level alarm was received.
(1212:03)


08:30:00	Power Operated Emergency Main Steam Dump Valve (MS-V3A) was shut.
(1230:37)




- 11 -