08:31:06	Decay Heat Removal Pumps 1A and 1B (DH-P-1A and DH-P-1B) were 
(1231:43)
 		started.
   


08:54:56	Core Flood Tank A alarm printed out at a level of 13.13 feet.
(1255:33)


09:04:18	Reactor Coolant Makeup Pump C (MU-P-1C) was stopped.
(1304:55)


O9:49:44	Reactor Building Isolation and Containment Spray were actuated by
(1350:21)
 		Engineered Safeguards.  Engineered Safeguards actuation started

		Reactor Coolant Makeup Pump C (MU-P-1C) and Reactor Building Spray

 		Pumps A and B (BS-P-1A and BS-P-1B).



09:49:50	Reactor Building Spray Valves (BS-V1A and BS-V1B) opened.
(1350:27)


09:49:58	Reactor Coolant Pumps 1A and 1B (RC-P-1A and RC-P-1B) inlet air
(1350:35)   
 		temperature high alarms annunciated and Pressurizer Safety Valves 
            
 		(RC-R1A and RC-R1B) discharge line temperature high alarms annun-

 		ciated.



09:50:24	Reactor Coolant Makeup Pump C (MU-P-1C) was stopped.
(1351:01)


09:55:30	Reactor Building Spray Pumps A and B (BS-P-1A and BS-P-1B) were
(1356:07)
 		stopped.



09:56:58	Decay Heat Removal Pumps A and B (DH-P-1A and DH-P-1B) were
(l357:35)
 		stopped.


10:24:00	Reactor Coolant System hot leg Loop A temperature decreased to
(1424:37)
Approximate	within the instrumentation range.


- 12 -