Event Recorder Printout of Three Mile Island Accident


Page 14





13:02:23	Condenser Vacuum Pump 1C (VA-P-1C) was started.
(1703:00)
   

13:08:22	Norma1 steam generator feedwater supply was put in service.
(1708:59)
Approximate


13:13:10	Condenser Vacuum Pump 1A (VA-P-1A) was started.
(1713:47)


13:23:04	Reactor Coolant Makeup Pump C (MU-P-1C) was started.
(1723:41) 

14:43:15	Reactor Coolant Makeup Pump C (MU-P-1C) was stopped.
(1843:52)


14:54:00	RCS pressure reached 2350 psig.
(1854:37)
Approximate


15:24:00	Reactor Coolant Pump 1A (RC-P-1A) was started.
(l924:37)


15:24:10	Reactor Coolant Pump 1A (RC-P-1A) was stopped.
(1924:47)
Approximate


16:04:00	Reactor Coolant Pump 1A (RC-P-1A) was started.
(2008:37)


22:15:00	Reactor Coolant System and Steam Generator conditions were:
(0215:37)
Approximate	Reactor Coolant System pressure = 1065 psig.

		Pressurizer Temperature = 551F (pressurizer heaters maintaining 

 			temperature).

 		Pressurizer Level = 397 inches.

 		Reactor Coolant System cold leg Loop A temperature = 288F

 		Steam Generator A steaming to the Main Condenser.




- 14 -