Event Recorder Printout of Three Mile Island Accident


Page 9





02:56:19	Steam Genarator B was isolated.  Main Steam Iso1atian Valves
(0656-56)    
Approximate	(MS-V4B and MS-V7B) were shut.


03:00:00	Reactor Coolant System pressure increased to 2130 psig.
(0700:37)
Aproximate


03:03:39	Steam Generator A pressure control was shifted from the Turbine Bypass
(0704:16)
Approximate	Valves (MSV-25A and B and MSV-26A and B) to the Power Operated

		Emergency Main Steam Dump Valves (MSV-3A and B).


03:10:27	Emergency Feedwater Pump 2A (EF-P-2A) was stopped.
(0711:04)


03:l2:28	Electromatic Relief Block Valve (RC-V2) was opened.
(0713:05)
Approximate


03:12:53	Reactor Coolant Pump 2B (RC-P-2B) was stopped.
(0712:53)  


03:20:13	Reactor Coo1ant Makeup Pump C (MU-P-1C) was started.  Reactor Coolant
(0720:41)
		Makeup Pumps C and A (MU-P-C and A) were operating.


03:23:23	General Emergency was declared. Notifications to offsite
(0724:00)
Approximate 	authorities and organizations were initiated.


03:30:00	Electromatic Relief Block Valve (RC-V2) was shut.
(0730:37)
Approximate
   

03:35:08	Emergency Feedwater Pump 2A (EF-P-2A) was started.
(0735:43)


03:37:00	Reactor Coo1ant Makeup Pump C (MU-P-1C) was stopped.
(0737:37)


03:51:00	Electromatic Relief Block Valve (RC-V2) was opened.
(0751:37)
Approximate


- 9 -